Mitsubishi PLK-E1010 Instruction Manual

(3) After the mechanical home position setting, tighten the detector plate fix screws (No.1) securely. (4) If the shift amount of home position by using this method enough. Please adjust by following procedure. (5) Remove the detector adaptor fix screws (No.3). (6) Replace the detector adaptor (No.4) to other position. In this case if move the detector adaptor (No.4) to the right, the mechanical home position is moved to the right and if it is moved to the left, the mechanical home position is moved to the left. (7) After setting, tighten the detector adaptor fix screws (No.3) securely. [NOTE] When the original mechanical home position is shifted. Please check the

clearance between the X detector plate and the X detector. This clearance should be set within the range of 1.0 ~ 1.5 mm.

1

2

4

3

7-19-2. Shifting the mechanical home position to the Y direction (1) Loosen the Y-detector setscrew (No.1).

(2) If move the Y-detector (No.2) to the front , the mechanical home position is shifted to the backward. If it is moved to the backward , the mechanical home position is shifted to the front. (3) After the mechanical home position setting, tighten the screw (No.1) securely.

2

1

7-20 Adjustment of the X-Y contact pressure

― 33 ―