Reece 32

A20

G. GENERAL TROUBLESHOOTING· CHART

MACHINE CONDITIONS

SYMPTOM

TEST-REM EDY

24 vc!ts de not

MAIN SWITCH Push to Stop Check to make certain that the fuse is a 6/ 10 ampere fuse,

G6 Check for short circuit in 24 volt system

available - possible

by the following procedure:

short circuit. (continued)

Part No. 04-0476.

(1) Insert new Transformer Safety 6/ 10 amp. fuse (04-0476) (2) Remove Control Circuit Board (3) Disconnect red wire from large capacitor (22,000 uf) (4) Disconnect one red wire coming from the 24 volt Transformer at the Diode Bride Rectifier. (5) Connect a 24 volt test lamp in series moved. (Use Lamp, 04-0253-0-380 mounted in Lamp Holder, 04-0252- 0-008 for 24 Volt test lamp) (6) Pull Main Switch to On, and Selec- tor Switch to "E" or "P & E". If 24 volt test lamp lights, there is a short circuit in the 24 volt system. Make a continuity check through all switches and wiring until the short is located. Make a visual check in the area of the Clamp Tabl~ For- ward switch and also where the ma- chine harness goes through the table frame. Move the harness to help lo- cate possible chafed-wire shorts. between the red wire, just discon- nected and the rectifier terminal from which it has just been re-