1. CLAMP CIRCUIT TROUBLESHOOTING CHART
@ Set voltmeter to the 50 volt de scale. Connect the negative probe to ground
MAIN SWITCH__ Pull to Start
Clamp will not raise
P&E
automatically when SELECTOR
or 142 and the positive probe to 2V. If a 24 volt de reading is obtained, the Clamp Table Forward switch is good.
CLAMP TABLE,__ Forward
it should.
MAN FRONT
LOADING
..
If not, replace switch.
® Set the voltmeter to the 50 volt de scale. Connect the negative probe to 142 and the positive probe to 72. If a
Same as above
Same as above
24 volt de reading is obtained the LOADING switch is good. If not, replace ~itch.
@ Set voltmeter to the 50 volt de scale. Connect the negative probe to ground
Same as above,
Same as above
also:
FINGERS
or 142 and the positive probe to TP18. If a 24 volt de reading is obtained, the Fingers Down switch is good. If not, replace switch.
UP
@ Set voltmeter to the 50 volt de scale. Connect the negative probe to ground
Same as above
Same as above,
FINGERS
also:
or 142 and the positive probe to TP23. If a 24 volt de reading is obtained, the circuit board components and the FINGERS DOWN switch are good. If not, check switch and then replace board if necessary. scale. Connect the negative probe to 142 and the positive probe to SY. If a 24 volt de reading is obtained, the Auto Clamp-Up switch· is good. If not. re- place switch.
SEMI or AUTO
@ Set the voltmeter to the 50 volt de
Same as above
Same as above
@) Set the voltmeter to the 50 volt de scale. Connect the negative probe to
Same as above
Same as above,
also:
CLAMP SAFETY
ground or 142 and the positive probe to 122. If a 24 volt de reading is ob- tained, the CLAMP SAFETY switch is good. If not, replace the switch.
NORM
Same as above
Same as above
Repeat steps 10 and 1E
.,