A32 3. PATCH FOLDING CIRCUIT TROUBLESHOOTING CHART
TEST-REMEDY
MACHINE CONDITIONS ..
SYMPTOM
·® · Set voltmeter to the 50 volt de scale. Connect the negative probe to ground
Patch folders will not
MAIN SWITCH _Pull to Start
C~AMP TABLE __ Back SELECTOR __ ELEC
close when loader
or 142, and the positive probe to 52. The meter should read 24 volts de until the loader arm goes all the way in. At this point the circuit should open. If it does rot, reset the Patch Loader switch.
arm go~s in...
LOADING __ AUTO FRONT
@) Set voltmeter to the 50 volt de scale. Connect the negative probe to ground
MAIN SWITCH ___ Pull to Start
Patch folders will. not
stay open on AUTO SELECTOR __ p & E
LOADING_·_
AUTO FRONT
cycle.
or 142 and the positive probe to 3Y. If a 24 volt de reading is obtained, the Table Forward switch is good. If not, replace switch.
® Set voltmeter to the 50 volt de scale. Connect the negative probe to ground or 142 and the positive probe to 52. If a 24 volt de reading is obtained, the LOADING switch·and the Patch Loader switch are good. If not, replace faulty switch. Check for 24 volts de at Alternate TP7. If 24 volts de is present, replace circuit board. . .
Same as above
Same as above
CLAMP TABLE - 8.ick