Reece 32
A35
4. AUTOMATIC PATCH LOADING CIRCUIT TROUBLESHOOTING
SYMPTOM
MACHINE CONDITIONS
TEST-REMEDY
@ Set voltmeter to the 50 volt de scale. Connect the negative probe to ground
Patch Loader wi 11 not
MAIN SWITCH __ Pull to Start
start.
_p & E
SELECTOR
CLAMP TABLE_Back
or 142, and the positive probe to 4Y. If a 24 volt de reading is obtained, the Fingers Down Safety switch is good. If not, replace switch.
LOADING
AUTO FRONT
@ Connect the negative probe to ground or 142, and the positive probe to 1Y.
Same as above
Same as above
·If a 24 volt de reading is obtained, the Clutch Dog switch is good. If not, replace switch.
..
@ Connect the negative probe to ground or 142, and the positive probe to 1OZ. If a 24 volt de reading is obtained, the Patch switch (pedal) is good. If not, replace switch. @ Connect the negative probe to ground or 142, and the positive probe to 7Y. If a 24 volt de reading is obtained, the APL Motor (auto) Start switch is good. If not, replace switch. ® Connect the negative probe to ground or 142, and the positive probe to 132. If a 24 volt de reading is obtained, the Loader Motor switch and the Auto Sewing switch are both good. If not, replace faulty switch. (The Auto Sewing switch would most probably be the faulty one. @ Set the voltmeter to the 150 volt ac scale. Connect the probes to 14Y and 10Y. If a reading of 115 volts ac is obtained, the circuit board components are good. If not, replace board. §] Set the meter to the X 10 ohms scale. Connect the probes to 14Y and 1OY. If a reading of approximat~ly 10 ohms is obtained, the Patch Loader Motor is good. If not, replace motor.
Same as above
Same as above
Same as above
Same as above
Same as above
Same- as above
Same as above
Same as above
MAIN SWITCH__ Push to Stop
Same as above
From the Library of Superior Sewing Machine & Supply LLC