Reece 32
A36 4. AUTOMATIC PATCH LOADING CIRCUIT TROUBLESHOOTING
MACHINE CONDITIONS
TEST-REMEDY
SYMPTOM
@) VISUAL CHECK. Roller lever on Auto- matic Sew switch is closin~ when arm
Machirie Starts
MAIN SWITCH _. Pull to Start
sewing when loader CLAMP TABLE_ Back
SELECTOR __ELEC
arm.goes in.
goes in. Readjust switch (See page A58 .J Also check Patch Folding Safety switch.
LOADING ___ AUTO FRONT
® Set voltmeter to'.the 50 volt de scale. Connec~ the negativl! probe to ground
Patch Loader Motor does not stop when machine is sewing.
MAIN SWITCH_Pull to Start
P&E
SELECTOR LOADING
or 142 and the positive probe to 132. The 24 volt de circuit should be broken
AUTO FRONT
LOADER SEW_ ON Remove pa(ch tray arm. CLAMP TABLE __ Back Sewing circuit energized
when the Loader Motor switch is
actuated. If it is not, replace the Loader
Motor switch.
@ VISUAL CHECK. Check motor brake to see that motor does not coast beyond the opening of Loader Motor switch.
Same as above
Same as above
Machine fails to sew after Patch Loader
(Reference only)
See Sew/Center Dense Circuit Trouble-
shooting Chart page A39.
Motor Circuit is checked.
@ Set voltmeter to the 50 volt de scale. Connect the negative probe to ground
Patch loader ~ill not start in MANUAL
MAIN SWITCH __Pull to Start
SELECTOR__ P & E
operation for maintenance adjustments.
or 142 and the positive probe to 9Y. .If a 24 volt de reading is obtained, the Length switch is good. If not, replace
LOADING-··· MAN FRONT
CLAMP SAFETY_ REP CLAMP TABLE _ Back Knee switch __ Closed
switch.
® Set voltmeter to the 50 volt de stale. Connect the negative probe to ground or 142 and the positiv9 probe to 132. If a 24 volt de reading is obtained, the APL Motor Manual Start Switch and CLAMP SAFETY switch are good. If not, replace faulty switch.
Same as above
Same as above
From the Library of Superior Sewing Machine & Supply LLC
Made with FlippingBook - Online catalogs